_______________________________________________Dear Júlia,
do I understand you correctly that your change is really just the addition of some
w_min
property, get/set_status() handling of it and some conditional code in the weight update function? And am I right in that the behavior of the model currently in NEST would not be changed at all if the new property were set to -infinity by default?If the answers to these questions are close to “yes”, I think the best way to integrate your changes into the corresponding built-in modes would be by means of a pull request against NEST and/or NESTML.
If they are more towards “no” or “maybe”, I suggest, you come to one of our next open NEST video conferences, so we could discuss more directly.
Cheers,
Jochen!On 11.06.21 13:19, Julia Gallinaro wrote:
Dear NEST Community,
I have performed a small alteration on one model of NEST for a project I am working on (It is a minor alteration: I included a minimum hard bound for weights in the triplet STDP rule).
I now want to share the code for this project, and would like to know what is the best approach for doing this. Should I provide my copy of the altered model file together with my project scripts? Or is there another way of doing it, which is more appropriate?
I am sorry if that is a basic question, but it is the first time I change something on NEST code for a project.
Best,Júlia
_______________________________________________ NEST Users mailing list -- users@nest-simulator.org To unsubscribe send an email to users-leave@nest-simulator.org-- Dr. Jochen Martin Eppler Phone: +49(2461)61-96653 ---------------------------------- Simulation Laboratory Neuroscience Jülich Supercomputing Centre Institute for Advanced Simulation
------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------
Forschungszentrum Juelich GmbH
52425 Juelich
Sitz der Gesellschaft: Juelich
Eingetragen im Handelsregister des Amtsgerichts Dueren Nr. HR B 3498
Vorsitzender des Aufsichtsrats: MinDir Volker Rieke
Geschaeftsfuehrung: Prof. Dr.-Ing. Wolfgang Marquardt (Vorsitzender),
Karsten Beneke (stellv. Vorsitzender), Prof. Dr.-Ing. Harald Bolt,
Dr. Astrid Lambrecht, Prof. Dr. Frauke Melchior
------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------
NEST Users mailing list -- users@nest-simulator.org